FAQ 1: Kodi voteji yoyezera yofunikira pa chingwe cha 11kV ndi iti yopirira kuyezetsa malinga ndi IEC 60502-2?

Yankho:Malinga ndiIEC 60502-2muyezo, AC kupirira test voltage ya zingwe zovotera 11kV (U0​=11 kV) amawerengeredwa monga3×U03×U0​. Chifukwa chake, pa chingwe chokhazikika cha 11kV, mphamvu yoyeserera yofunikira ndi33kv ku. Kugwiritsa ntchito a60kV VLF AC Hipot Test Setimapereka zowonjezera zokwanira kuti zikwaniritse mulingo uwu ndikuwonetsetsa chitetezo cha zida ndi woyendetsa.

 

FAQ 2: Chifukwa chiyani njira ya VLF (Very Low Frequency) ndiyofunikira pazingwe zamakono za XLPE?

Yankho:Miyezo yapadziko lonse lapansi, kuphatikizaIEC 60502-2ndi IEEE 400.2, amalangizaNjira ya AC VLF (nthawi zambiri 0.1Hz)poyesa DC pazingwe za XLPE (Cross-Linked Polyethylene). Kuyesa kwa DC kumatha kupangitsa kuti "space charge" kuchulukirachulukira, zomwe zingayambitse kulephera kwa chingwe chikabwezeretsedwa. Kuyesa kwa VLF kumapereka mayeso enieni a kupsinjika kwa AC omwe amazindikira bwino zowonongeka popanda kuyambitsa polarization yoyipa.

 

FAQ 3: Kodi ndingagwiritse ntchito 60kV VLF Test Set pamakina onse a 11kV ndi 33kV?

Yankho:Inde. A60kV VLF AC Hipot Test Setndi zosinthika kwambiri. Popeza chingwe cha 11kV chimafuna kuyesa kwa 33kV ndi chingwe cha 33kV (U0=19 kapena 20 kVU0​{7}} kapena 20 kV) nthawi zambiri chimafuna mphamvu yoyesera pafupi ndi 57kV kapena 60kV, chipangizochi ndi "malo okoma" kwa makontrakitala. Zimakulolani kuti muzitha kuphimba magulu awiri omwe amapezeka kwambiri ogawa magetsi ndi chipangizo chimodzi, chonyamula.

Test Voltage Selection - what DC voltage should I apply for cable test?

FAQ 4: Kodi lamulo la "33kV Test Voltage" limagwira ntchito bwanji pazingwe zomwe zangoyikidwa kumene motsutsana ndi-zingwe zantchito?

Yankho: IEC 60502-2makamaka amalankhula "After Installation" (commissioning) gawo, amafuna3U03U0 (33kV pazingwe za 11kV). Pokonza kapena kuyesa "mu-ntchito" ya zingwe zakale, zida zina zitha kuchepetsa mphamvu yamagetsi kufika pa 2U02U0​ kapena 2.5U02.5U0​ kuti apewe kutsekereza kwa okalamba. Komabe, pakugawirana bwino kwa pulojekiti yatsopano, kukwaniritsa cholinga cha 33kV VLF ndiye muyezo wagolide wodalirika.

 

FAQ 5: Kodi maubwino a 0.1Hz omwe amagwiritsidwa ntchito mu 60kV VLF ndi chiyani?

Yankho:The0.1Hz pafupipafupindi "matsenga akuthupi" omwe amapangitsa kuti zidazo zizinyamula. Pa 50Hz, kuyesa chingwe chachitali cha 11kV kungafune thiransifoma yayikulu chifukwa champhamvu kwambiri. Pochepetsa pafupipafupi kukhala 0.1Hz, ndiKulipiritsa komwe kumafunikira kumachepetsedwa ndi nthawi 500. Izi zimalola athu60kV VLF Hipot Test Setkuti ikhale yophatikizika mokwanira kuti igwiritsidwe ntchito m'munda ndikuperekera mawonekedwe a sinusoidal waveform omwe amakwaniritsa zofunikira za metrology.